A voltage dip is a decrease of mains voltage, an interruption is a breakdown of mains voltage, and a variation is a continuous change of mains voltage.
Dips & Interrupts are caused by faults in the power network, the installation or by sudden large change of load, while voltage variations (optional by the standard) are caused by continuous varying loads connected to the power network.
The standard IEC 61000-4-11 defines immunity test methods and test levels for testing equipment connected to low-voltage power supply networks. It applies to equipment having a rated input current not exceeding 16 A/phase, for connection to 50 or 60 Hz AC networks.
IEC 61000-4-29 applies to voltage dips, short interruptions and voltage variations on DC input power port.
Product
Description
Single phase automatic 16 A coupling/decoupling networks (CDNs) for EFT/Burst, Surge, and Power Quality (Dips Interrupts & Variations) testing
Programmable AC/DC power source (3 - 15 kVA) for single and three phase applications
Single function generator for single phase Dips Interrupts & Variations testing up to 270 V/16 A in compliance with IEC 61000-4-11 and IEC 61000-4-29
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (4.4 kV), Dips Interrupts and Variations, and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (4.4 kV), Dips Interrupts and Variations, and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (6.6 kV), Surge Telecom 10/700, Ring Wave, Dips Interrupts and Variations, and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (6.6 kV), Dips Interrupts and Variations, Ring Wave (6.6 kV) and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Single phase 3 kVA system to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. Supporting testing on products consuming up to 11 Arms and 92 A peak @ 230 VAC
Single phase 5 kVA system up to 16 A to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
Three phase 15 kVA system (5 kVA per phase) up to 16 A to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
Three phase 30 kVA system (10 kVA per phase) up to 43 A to measure harmonics and flicker in accordance with IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11 and IEC 61000-3-12.
Three phase 45 kVA system (15 kVA per phase) up to 62 A to measure harmonics and flicker in accordance with IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11 and IEC 61000-3-12.